DUST COLLECTION
 
Considerable care must be taken to manage finely divided metal particles and dust. The appropriate NFPA or other applicable standards should be followed when designing, installing, operating, and maintaining dust collection systems.

While the following list is not all inclusive, it may help to know some of the common design requirements. Some key requirements for safe operation include:

  • The air velocity in conveying pipes must be greater than 4,500 fpm.
  • Downdraft or backdraft tables should have a minimum of 150 fpm air velocity at the surface.
  • An air curtain should have a flow of at least 400 fpm.
  • The mass of accumulated aluminum powder should not exceed 1 pound.

We offer both vacuum and filtration systems within our equipment or as accessories. For more information on the available devices please contact CenterLine.

Vacuums
CenterLine maintains a stock of custom explosion-rated vacuums. These powerful vacuums are integrated into our SSM-P3300-003 system but they can also be fitted with casters for other portable applications. These machines have a 1-1/2 HP motor operating at 220 V 60 Hz. They also include a HEPA filter for the discharge air.

 
Wet Filtration Systems
We currently have 2,000 cfm and 5,000 cfm sizes. The advantage of these systems is that they designed to trap the waste in water so that there is no chance of combustion. A supply of water and a drain must be provided. The escaping moist air is commonly vented to an area where it won’t cause a problem, such as outside the plant or office.

AIR PREPARATION   DUST COLLECTION   SPRAY BOOTHS   SAFETY EQUIPMENT